Settings

4 min readUpdated 2026-06-01

Project Settings

This page is relevant for ✅Studio ✅Player

Project settings
Project settings

Prj - General

Setting Description
Created Displays the timestamp of the project's creation.
Description Free text field for a project description.
ProjectFolder Displays the storage location of the project on the file system.
SpeedUpLoading Use the cache file to speed up loading. The cache file has the extension .plclab3d and is always generated automatically when the CAD file changes.

Prj - Permissions Management

Permissions management allows functions to be locked and errors to be introduced into the signal processing. The setting can be protected with a password. For example, an instructor can distribute a system with intentional errors, and the students must locate the error (Instructor-Mode).

Setting Description
Show error scenario (Tags) Shows the inserted errors in the Tags window. A sensor can be set to permanently provide True or permanently provide False.
Disable Skill-Manager Hides the Skill-Manager. This prevents the system from being modified. Editing the tags (symbols) is also no longer possible.
Disable RUN-Mode Disables the simulation mode. The user can only view the system but not simulate it.
Disable Autopilot The autopilot is locked.
Password Input field to set or reset a password for permissions management.
Set password Sets a new password. A password must be provided.
Reset password Removes the set password. The password must be provided.

Inserting Errors:

The Show Failure Injection button can be used to display and edit the built-in failures:

Show Failure Injection
Show Failure Injection
Image Description
Add Errors (2): Using the buttons 0 and 1, errors can be inserted for each symbol. If 1 is shown in red, a sensor will always provide True. An actuator would always have the value True. (1): The number of existing errors is displayed here. This display is always visible if errors are present.

Now create a ZIP file for the student:

Share ZIP Students
Share ZIP Students

The ReadOnly4Students switch causes the 3D simulation in the ZIP file to be password-protected with a random password. The simulation cannot be modified. Even the built-in errors cannot be displayed or removed. This allows you, as an instructor, to distribute a faulty system and have the students locate the errors (Instructor Mode).

Important

A ZIP file with the ReadOnly4Students switch can no longer be edited in PLC-Lab 3D Studio because it is protected with a random password. This is therefore not a backup of the project.

Prj - Backups of Skill Settings

This section allows old skill settings to be restored. Backups of the skill settings are made automatically and could be restored here.

Setting Description
Description Description/comment of the backup.
TimeStampInfo Timestamp of the backup.
PreviousSettingsBackupFile Filename of the settings.
Button Restore this setting If this button is pressed, these skill settings will be applied the next time the project is loaded.

Prj - Buttons

Various actions that can be triggered via buttons.

Button Description
Show folder in Windows Explorer. Windows Explorer is opened.
Backup Skill-Settings A backup is created for the skill settings. This usually does not need to be triggered manually, as backups are always created when changes are made.
RemoveAllCameraPositions All camera positions are deleted and can be redefined.

General Settings

Setting Description
Theme Choice between the Dark and Light UI themes.
Audio On Enables/Disables sound playback in 3D Studio.
Maximize window on start When starting PLC-Lab 3D Studio: Starts the app window in a maximized state.
Time Scale Controls the simulation speed. Default=1

Mouse/Keyboard Control

Setting Description
Mouse Sensitivity Determines the responsiveness of mouse movement. Default=0.5.
Mouse Wheel Sensitivity Controls the zoom speed with the mouse wheel. Default=0.5.
Keyboard Sensitivity Sets the repeat rate of keyboard inputs. Default=0.5.

Network Settings for Device-Connector

Setting Description
Port TCP port for the connection to the controller/PLC. Default=8080.
IP IP address of the Device-Connector. The Device-Connector normally starts on the same computer. Default=localhost.
Selected Network-Interface Selection of the network adapter to be used.
Polling Rate in ms Query interval for input/output values in milliseconds via the Device-Connector. Default = 5ms

Video Settings

Setting Description
DefaultFontSize Font size in the user interface. Default=14
Target Framerate Target frame rate for the simulation. Default=60.
Brightness General brightness of the scene. Default=1.5.
Quality-Level Sets the render quality (e.g., shadows, details). 4=Best quality.
FullScreen Switches to full-screen mode when the Apply button is pressed.
ResolutionString Selection of the desired resolution. This selection only makes sense in full-screen mode.