Settings
Project Settings
This page is relevant for ✅Studio ✅Player

Prj - General
| Setting | Description |
|---|---|
| Created | Displays the timestamp of the project's creation. |
| Description | Free text field for a project description. |
| ProjectFolder | Displays the storage location of the project on the file system. |
| SpeedUpLoading | Use the cache file to speed up loading. The cache file has the extension .plclab3d and is always generated automatically when the CAD file changes. |
Prj - Permissions Management
Permissions management allows functions to be locked and errors to be introduced into the signal processing. The setting can be protected with a password. For example, an instructor can distribute a system with intentional errors, and the students must locate the error (Instructor-Mode).
| Setting | Description |
|---|---|
| Show error scenario (Tags) | Shows the inserted errors in the Tags window. A sensor can be set to permanently provide True or permanently provide False. |
| Disable Skill-Manager | Hides the Skill-Manager. This prevents the system from being modified. Editing the tags (symbols) is also no longer possible. |
| Disable RUN-Mode | Disables the simulation mode. The user can only view the system but not simulate it. |
| Disable Autopilot | The autopilot is locked. |
| Password | Input field to set or reset a password for permissions management. |
| Set password | Sets a new password. A password must be provided. |
| Reset password | Removes the set password. The password must be provided. |
Inserting Errors:
The Show Failure Injection button can be used to display and edit the built-in failures:

| Image | Description |
|---|---|
![]() |
(2): Using the buttons 0 and 1, errors can be inserted for each symbol. If 1 is shown in red, a sensor will always provide True. An actuator would always have the value True. (1): The number of existing errors is displayed here. This display is always visible if errors are present. |
Now create a ZIP file for the student:

The ReadOnly4Students switch causes the 3D simulation in the ZIP file to be password-protected with a random password. The simulation cannot be modified. Even the built-in errors cannot be displayed or removed. This allows you, as an instructor, to distribute a faulty system and have the students locate the errors (Instructor Mode).
A ZIP file with the ReadOnly4Students switch can no longer be edited in PLC-Lab 3D Studio because it is protected with a random password. This is therefore not a backup of the project.
Prj - Backups of Skill Settings
This section allows old skill settings to be restored. Backups of the skill settings are made automatically and could be restored here.
| Setting | Description |
|---|---|
| Description | Description/comment of the backup. |
| TimeStampInfo | Timestamp of the backup. |
| PreviousSettingsBackupFile | Filename of the settings. |
| Button Restore this setting | If this button is pressed, these skill settings will be applied the next time the project is loaded. |
Prj - Buttons
Various actions that can be triggered via buttons.
| Button | Description |
|---|---|
| Show folder in Windows Explorer. | Windows Explorer is opened. |
| Backup Skill-Settings | A backup is created for the skill settings. This usually does not need to be triggered manually, as backups are always created when changes are made. |
| RemoveAllCameraPositions | All camera positions are deleted and can be redefined. |
General Settings
| Setting | Description |
|---|---|
| Theme | Choice between the Dark and Light UI themes. |
| Audio On | Enables/Disables sound playback in 3D Studio. |
| Maximize window on start | When starting PLC-Lab 3D Studio: Starts the app window in a maximized state. |
| Time Scale | Controls the simulation speed. Default=1 |
Mouse/Keyboard Control
| Setting | Description |
|---|---|
| Mouse Sensitivity | Determines the responsiveness of mouse movement. Default=0.5. |
| Mouse Wheel Sensitivity | Controls the zoom speed with the mouse wheel. Default=0.5. |
| Keyboard Sensitivity | Sets the repeat rate of keyboard inputs. Default=0.5. |
Network Settings for Device-Connector
| Setting | Description |
|---|---|
| Port | TCP port for the connection to the controller/PLC. Default=8080. |
| IP | IP address of the Device-Connector. The Device-Connector normally starts on the same computer. Default=localhost. |
| Selected Network-Interface | Selection of the network adapter to be used. |
| Polling Rate in ms | Query interval for input/output values in milliseconds via the Device-Connector. Default = 5ms |
Video Settings
| Setting | Description |
|---|---|
| DefaultFontSize | Font size in the user interface. Default=14 |
| Target Framerate | Target frame rate for the simulation. Default=60. |
| Brightness | General brightness of the scene. Default=1.5. |
| Quality-Level | Sets the render quality (e.g., shadows, details). 4=Best quality. |
| FullScreen | Switches to full-screen mode when the Apply button is pressed. |
| ResolutionString | Selection of the desired resolution. This selection only makes sense in full-screen mode. |